EasyManuals Logo

Daikin FAQ71BVV1B Service Manual

Daikin FAQ71BVV1B
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #109 background imageLoading...
Page #109 background image
Si20-701_B Troubleshooting by Remote Controller
102
3.11
A9
Electronic Expansion Valve
Coil (Y1E) Abnormality
Remote Controller Display
A9
Applicable Models
FMCQ, FMDQ
Method of Error Detection
Use a micro-computer to check the electronic expansion
valve for coil conditions.
Error Decision Conditions
When the pin input of the electronic expansion valve is
not normal while in the initialization of the micro-
computer.
Supposed Causes
îš„ Defective electronic expansion valve coil
îš„ Defective indoor unit PCB
îš„ Defective connecting cable