EasyManuals Logo

Daikin FAQ71BVV1B Service Manual

Daikin FAQ71BVV1B
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #225 background imageLoading...
Page #225 background image
Si20-701_B Troubleshooting by Remote Controller
218
3.38
F3
Discharge Pipe
Temperature Control
Remote Controller Display
F3
Applicable Models
RZQ-K/H, RZQ(S)-B/C, RZQG, RZR-KU / HU
Method of Error Detection
The error is detected according to the temperature
detected by the discharge pipe thermistor.
Error Decision Conditions
îš„ When the discharge pipe temperature rises to an
abnormally high level
îš„ When the discharge pipe temperature rises suddenly
îš„ When the discharge pipe temperature does not rise
after operation start
Supposed Causes
îš„ Defective discharge pipe thermistor
îš„ Defective connection of discharge pipe thermistor
îš„ Refrigerant shortage
îš„ Defective compressor
îš„ Disconnection of discharge pipe thermistor
îš„ Defective outdoor unit PCB

Table of Contents

Other manuals for Daikin FAQ71BVV1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FAQ71BVV1B and is the answer not in the manual?

Daikin FAQ71BVV1B Specifications

General IconGeneral
BrandDaikin
ModelFAQ71BVV1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals