SiUS04-924 Outdoor Unit
180 Removal Procedure
2.7 Removal of Compressor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembly work.
Step Procedure Points
1
Remove the terminal
cover.
2
Pull out the 3 leads
using long-nose pliers.
U:red, V:yellow, W:blue
3
Remove the OL.
(R9650)
(R9471)
W(blue)
U(red)
V(yellow)
OL