SiUS04-924 Control Specification
36 Function and Control
Frequency
Compressor
Four-way valve
Fan
Electronic expansion
valve opening
ON
OFF
ON
OFF
ON
OFF
0 Hz
39 Hz
62 Hz
5 sec.
350 pulse 400 pulse
450 pulse
Initial opening
PI control
5 sec.
60 sec.
60 sec. 650 sec. (Max. limit)
120 sec.
(R9868)
Outdoor temp. 3 32°F(0°C)