SiUS04-924 Service Check Function
Service Diagnosis 71
5. Press the TEMP button.
Press TEMP
or buttonand change the figure until you hear the long sound of “beep”.
6. Diagnose by the sound.
beep : The left-side numeral is incorrect; move to the next number.
beep-beep: The left-side numeral is incorrect but the right-side numeral is correct. .
“beep” : Both the right & left numerals are the correct error codes designators.
7. Determine the error code.
The figure indicated when you hear the long “beep” sound is the error code.
(Error codes and description
Refer to page 72.)
8. Press the MODE button to exit from the diagnosis mode.
The display “ ” means the trial operation mode.
(Refer to page 183 for trial operation.)
9. Press the ON/OFF button twice to return to the normal mode.
Note: When the remote controller is left untouched for 60 seconds, it returns to the normal mode.
(R8383)
(R8384)
(R9879)
(R9660)