3.8.4 LXE10E-1 & LXE10E-A Initial setting table into spare controller DECOSd
Note 1. Comfirm MODEL NAME stamped in the name plate mounted on the reefer unit.
MODEL NAME
Note 1
10.Optional fun.
11.Basic function mode
USdA
dHu
DECOS3
LOG INT
REC SEN
OC-SET
HP
dISP
COMP
REHEAT
FASEN
C/F
CHARTLS
USdA1/2
H001 H002
H003
H004
H005
H006
D1--
D2-- D3--
D4--
D5--
SET ID
LXE10E-A5C
to
LXE10E-A5E
OFF
OFF d 30 ON
Sing
10
OFF
100
OFF
OFF C
OFF
1
3
2
2
2
3 3 1 1
1
1
1
LXE10E-A9B
OFF
OFF d
30
ON
Sing
10
OFF
100
OFF OFF
C
OFF
1
3
2
2 2 3 3
1
1
1
1 1
LXE10E-A12C
to
LXE10E-A12F
OFF OFF
d
30
ON
Sing
10
ON
100
OFF OFF
C
OFF
1
3
2
2 2 3 3
1
1
1
1 1
LXE10E-A15C
to
LXE10E-A15J
OFF
OFF d 60 ON
Sing
10
OFF
100
ON
OFF C ON 2
3
2
2
2
3
3
1 1
1
1
1
LXE10E-A27B
OFF OFF
d
60
ON
Sing 10 OFF 100 ON OFF
C
ON
2
3 2 2 2
3
3
1
1 1 1 1
LXE10E-A29A
OFF
OFF d
30
ON
Sing
10
OFF
100
OFF OFF
C
ON
1
3
2
2
2
3 3 1 1
1
1
1
LXE10E-A31A
LXE10E-A31B
OFF
OFF d 60 ON
Sing
10
OFF
100
ON
OFF C ON 2
3
2
2
2
3
3
1 1
1
1
1
LXE10E-A32A
LXE10E-A32B
OFF OFF
d
60
ON
Sing
10
OFF
100
ON
H C
OFF
2
3
2
2
2
3 3 1 1
1
1
1
LXE10E-A33
LXE10E-A33A
OFF OFF
d
60
ON
Sing
10
OFF 100 ON OFF
C
ON
2
3
2
2 2 3 3
1
1
1
1 1
LXE10E-A35
LXE10E-A35A
LXE10E-A35B
OFF
OFF d 30 ON
Sing
10
OFF
100
OFF
OFF C
OFF
1
3
2
2
2
3 3 1 1
1
1
1
LXE10E-A36
LXE10E-A36A
OFF OFF
d
60
ON
Sing
10
OFF 100 ON OFF
C
ON
2
3
2
2 2 3 3
1
1
1
1 1
LXE10E-A40
OFF
OFF d 30 ON
Sing
10
OFF
100
OFF
OFF C
OFF
1
3
2
2
2
3 3 1 1
1
1
1
12.Optional Condition mode
13.Input Data
SET TIME
GMT
GMT
GMT
GMT
LXE10E-A15BR
LXE10E-A15GR
OFF OFF
d
60
ON
Sing 10 OFF 100 ON OFF
C
ON
2
3
2
2 2 3 3
1
1
1
1 1
GMT
LXE10E-A18B
to
LXE10E-A18D
OFF
OFF d
60
ON
Sing
10
OFF
100
ON
OFF C
OFF
1
3
2
2
2
3 3 1 1
1
1
1
GMT
LXE10E-A19A
OFF OFF
d
30
ON
Sing
10
OFF 100 OFF OFF
C
OFF
1
3 2 2 2
3
3
1
1 1 1 1
GMT
LXE10E-A21B
LXE10E-A21D
OFF OFF
d
30
ON
Sing
10
OFF 100 OFF OFF
C
ON
1
3
2
2
2
3 3 1 1
1
1
1
GMT
LXE10E-A23
LXE10E-A23A
to
LXE10E-A23C
OFF OFF
d
60
ON
Sing
10
OFF
100
OFF OFF
C
ON
2
3
2
2
2
3 3 1 1
1
1
1
GMT
+8
LXE10E-A26B
to
LXE10E-A26D
OFF OFF
d
60
ON
Sing
10
OFF 100 ON OFF
C
OFF
2
3
2
2
2
3 3 1 1
1
1
1
GMT
GMT
GMT
GMT
GMT
GMT
GMT
GMT
GMT
LXE10E-A37
OFF OFF
d
30
ON
Sing
10
ON
100
OFF OFF
C
ON
1
3
2
2
2
3 3 1 1
1
1
1
GMT
LXE10E-1
LXE10E-1A
to
LXE10E-1E
AU OFF
d
60
ON
Sing
10
OFF 100 ON L
F
ON
2
3
2
2
2
3 3 1 1
1
1
1
GMT
03LXE10E-A(33-47)07.2.232:21PMページ3-47
https://daikin-p.ru

Table of Contents

Related product manuals