SiBE81-909 Troubleshooting
Humidifying Air Purifier 61
7.4.5 The odor / dust / humidity sensor lamp does not light.
1
Models Covered
5
Troubleshooting
MCK75JVM-K
Diagnosis Remedy
This is not a failure.
Connect the flat
cable.
[S129, S400]
Replace the dis-
play PCB or the
operation PCB.
Go to on
P. 6 4 .
2
Method of Mal-
function Detection
3
Malfunction Deci-
sion conditions
4
Supposed Causes
The flat cable is improperly con-
nected.
The display PCB is defective.
The operation PCB is defective.
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
If the brightness
adjustment button is
pressed, is the lamp
turned on?
Is the flat cable
linking the display
PCB and the
operation PCB
connected?
Yes
No
No
Yes
Check1