SiBE81-909 Removal Procedure
Humidifying Air Purifier 89
8.8 Removal of Power Cord
Warning Be sure to wait 10 minutes or more after turning off all power supplies before
disassembling work.
Step Procedure Points
1. Removable of the power
cord
1
Remove the 3 screws
from the casing frame.
Remove the power
cord.
2
Remove the 3 screws
from the bottom.
3
Lift up the casing frame
to remove.
(R9837)
Place the bush
horizontally.
Power cord
(R9838)
Casing frame
(R9839)