Removal Procedure SiBE81-909
78 Humidifying Air Purifier
8.5 Removal of Display / Operation PCB
Warning Be sure to wait 10 minutes or more after turning off all power supplies before
disassembling work.
Step Procedure Points
1. Removal of the
operation sign cover
1
Remove the 2 screws
from the back side.
2
Untie the power cord.
3
Remove the 5 screws
from the back cover.
(R9812)
(R9766)
Power cord
(R9767)