Parts List
Below is a partial list of applied rooftop unit replacement
parts. Contact a local sales representative for additional
information
Table 26:
Component
designation
Description
Daikin part number
MCB Main control board 060006101
CCB1 Auxiliary cooling control board (DX Circuit #1 or generic condenser) 112026101
(replaces 106102701)
CCB2 Auxiliary cooling control board (DX circuit #2) 112026101
(replaces 106102701)
EHB1 Auxiliary electric heat control board 112026101
(replaces 106102701)
ERB1 Auxiliary energy recovery control board 112026101
(replaces 106102801)
RS-485 communication module (for auxiliary control boards) 060006202
Standoffs for mounting RS-485 communication module (PN 060006202) onto auxiliary control board (PN
112026101)
048166707
Keypad/display 060006301
Keypad, main control board cable 111044601
ZNT1 Zone temperature sensor with tenant override 111048101
Zone temperature sensor with tenant override & remote setpoint adjustment (SCC units only) 111048102
DAT Discharge air temperature sensor (50 ft cable length-field cut to length) 060004705
ENT Entering fan air temperature sensor (50 ft cable length-field cut to length) 060004705
OAT Outside air temperature sensor (50 ft cable length-field cut to length) 060004705
RAT Return air temperature sensor (50 ft cable length-field cut to length) 060004705
SPS1 Static Pressure sensor: duct, No. 1 049545007
SPS2 Static pressure sensor: duct, No. 2 049545007
Static pressure sensor: building (space) pressure 049545006
T2 Transformer: 115/24 VAC 060004601
T3 Transformer: 115/24 VAC 060004601
T9 Transformer: 115/24 VAC 060630801
HUM1 Humidity sensor: wall mount 067294901
Humidity sensor: duct mount 067295001
PC5 Dirty filter switch: first filter section 065493801
PC6 Dirty filter switch: final filter section 065493801
PC7 Airflow proving switch 060015801
DHL Duct high limit switch 065493801
OAE Enthalpy control: electromechanical 030706702
Enthalpy control: electronic (used with RAE) 049262201
RAE Return air enthalpy sensor (used with electronic OAE) 049262202
SD1 Smoke detector: supply air 049025001
SD2 Smoke detector: return air 049025001
BACnet MS/TP communication module (RS-485) 060006202
BACnet/IP communication module (IP cable 10BASET) 060006201
–L
ON
M
ARK
space comfort controller (SCC) communication module 060006203
–L
ON
M
ARK
discharge air controller (DAC) communication module 060006204
5 VDC precision power supply 111049610
Serial port ribbon cable 111047201
–MCB battery BR2325
MCB connector repair kit 300036605

Table of Contents

Other manuals for Daikin MicroTech II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin MicroTech II and is the answer not in the manual?

Daikin MicroTech II Specifications

General IconGeneral
BrandDaikin
ModelMicroTech II
CategoryController
LanguageEnglish

Related product manuals