MANUALE INSTALLATORE RELEASE 00.1 PAG. 20
ALARM CONTROL
The electronic system of this espresso machine manages all machine functions and controls their
correct execution.
In case of anomalies, an alarm is recorded and/or displayed.
An alarm can be triggered also by an improper use of the espresso machine. In this case, it will
be sufficient to correct the improper use.
Some alarms are non-influential for the proper functioning of the machine and, more importantly,
for the user's safety. These alarms are not stored in the system memory. These alarms will be
marked with “A”.
Other alarms are displayed and recorded with their triggering date and time. They can block the
anomalously functioning part. These alarms will be marked with “ABP”.
Finally, there are a few alarms that totally block the machine and are marked as “ABT”.
Type “A” alarms
"Gr.1 time-out",
This alarm is triggered when an extraction is made on group 1 through the P5 – “continuous
pouring” button for more than 120 seconds.
"Gr.2 time-out",
This alarm is triggered when an extraction is made on group 2 through the P5 – “continuous
pouring” button for more than 120 seconds.
"Gr.3 time-out",
This alarm is triggered when an extraction is made on group 3 through the P5 – “continuous
pouring” button for more than 120 seconds.
"Gr.4 time-out",
This alarm is triggered when an extraction is made on group 4 through the P5 – “continuous
pouring” button for more than 120 seconds.
"Steam time-out",
This alarm is triggered when steam is produced through the MCS but the milk temperature probe
does not reach 30°C within 60 seconds.
Type “ABP” alarms
"Steam boiler time-out",
This alarm is triggered when the steam boiler does not reach the temperature of 40°C within 10
minutes of turning on. Push the DEL button on display to delete the alarm.
"Boiler probe interrupted"
This alarm is triggered when boiler temperature probe is out of the range.
"Boiler probe short circuit"
This alarm is triggered when boiler temperature probe is out of the range.
"Boiler high temperature"
This alarm is triggered when boiler temperature probe is out of the range, exceeding 127,5°C.
"Steam probe interrupted"
This alarm is triggered when MCS probe is out of the range.