63 Spyder2 User’s Manual
03-032-10091-06 Teledyne DALSA
Code Command Short
Form
Parameters Description
18 hel p
h
Display the online help.
19 region_of_i nterest
roi i i
Set the pi xel range for readi ng
end-of-
line statistic and for the
region of pi xels used in the
cag, cao, gl, gla, ccf, and
ccp commands. Pixel start and
end values in a range from 1 to
20 reset_camer a
rc
Reset the enti re camer a
(reboot).
21 reset_pi xel _coef fs
rpc
Reset the pi xel coef fi cients to 0.
22 restore_factory_settings
rfs
Restor e the camera’s factory
settings. FPN and PRN U
coeff i cients reset to 0.
23 restor e_user _settings
rus
Restor e the camera's l ast saved
user setti ngs and FPN and
24 set_analog_offset
sao t i
Set the analog offset. The first
parameter i s the tap selection
either 1 or 0 for all taps. The
second parameter controls the
digital analog convertor
(DA C), in a range from 0 to
1023, w hich sets anal og offset.
Off set increases w i th hi gher
val ues.
25 set_baud_rate
sbr i
Set speed of serial
communication port. Baud
rates: 9600 (default), 19200,
26 set_camera_id
sci s [s]
Set camer a ID . The fir st
parameter is a character A to Z,
or 0 to 9. The second optional
parameter i s the ser i al number
of the addressed camer a.
27 set_data_mode
sdm i
Set the data mode of camera
output to:
0: 8-
single pr ocessor
1: 10-bit,
ports, si ngl e processor
2: 8-bit, A / B and D/ E ports,
dual processor
3: 10-
ports, dual pr ocessor