7 Spyder2 User’s Manual
03-032-10091-06 Teledyne DALSA
Optical Interface Units Notes
Sensor Alignment
x, y
z
Υz
Parallelism/ Tilt
µm
mm
°
µm
±180
17.52 ± 0.25 (C-Mount)
46.50 ± 0.25 (F-Mount)
± 0.6
<175
Die Surface Flatness
µm
100
Lens Mount C or F mount
Camera Thread
M 42x1
Mechanical Interface Units Notes
Camera Size
mm
50 x 85 x 50
M ass Kg < 450 g
Connectors
data connector
power connector
M DR26 (female)
H i r ose 6-pin (male)
Electrical Interface Units Min Nom Max Notes
Input Voltage
Volts
+12 to +15
Power Dissipation
W
< 5
Oper ati ng
Temperature
°C 10 50
M easur ed at
the front
pl at e.
Camera Performance Units
Min. Nom. Max. Notes
Line Rate kHz 1 65 (512)
35 (1024)
18 (2048)
Data Rate
MHz
40
40
Data Format 8 bit 10 bit
8 or 10 bit
user
selectable.
N ominal Gain Range
dB
-10
+10
Dynamic Range DN:DN
330:1 500:1
Pi xel Response N on-
Uniformity (PRNU)
uncorrected
corrected (ECD/ ECE)
DN
5
1.2/ 1.5
23
6/8
1
FPN
uncorr ected
corrected
DN p-p
3.5
1
8
3
Random Noise DN rms 0.5
0.75
2.2
1.2
4
@-10dB gain
@0dB gain
@+10dB gain