8 Spyder2 User’s Manual
03-032-10091-06 Teledyne DALSA
Camera Performance Units
Min. Nom. Max. Notes
Calibrated DC Offset DN 3
5
17
@-10dB gain
@0dB gain
@+10dB gain
Antiblooming 100x
Responsi v i ty DN/ (nJ/
cm
2
)
13.6±2
42.8±5
136.0±16
@-10dB gain
@0dB gain
@+10dB gain
Power Up Duration sec 15
SEE n J/ cm
2
5.79
@530nm,
0dB
N EE p J/ cm
2
37.3
@530nm,
0dB
Regulatory
Regulatory Compliance
CE and FCC
Shock and Vibration MIL-STD -810E
DN = Digital Numbers (0-255); also know n as gray l ev el s.
1. ECD= Exposure control disabled. When operating the camera in exposure mode 2
(see section 3.9 Setting Line Rate and Exposure Mode for details), exposure control is
disabled until the
set command i s sent. A l l other exposur e m odes oper ate w i th ECE
or exposure cont r ol enabl ed.
Test conditions unless otherwise noted:
• All measurements taken in 8 bit mode
• Data Rate: 40 M H z
• Line Rate: maximum (FPN and PRNU measured at minimum line rate), DC-Offset to
be characteri zed ov er different line r ates
• Nominal Gain setting, unless specified
• Light Source: Broadband Quartz Halogen, 3250K, with 750nm cutoff filter installed
• Ambient test temperature: 25 °C
• De-rating specifications for temperature range from 0 °C to 50 °C