Amp Prot
A numerical value indicating the number of times the D12 has entered
the error condition "Amp Protect", possibly due to a current overload
caused by a low impedance or short circuit connected to the output.
Amp Err
A numerical value indicating the number of times the D12 has entered
the error condition "Amp Error" due to an internal fault.
Temp Off
A numerical value indicating the number of times the D12 has switched
off with the error condition "Overtemperature" due to overheating.
ImpErrLf
A numerical value indicating the number of times the D12 has entered
the error condition "ImpErrLf" due to a Load Monitoring fault.
ImpErrHf
A numerical value indicating the number of times the D12 has entered
the error condition "ImpErrHf" due to a Load Monitoring fault.
InpMonErr
A numerical value indicating the number of times the D12 has entered
the error condition "InpMonErr" due to a Input Monitoring fault,
possibly caused by a missing external pilot signal.
T/S Mis.
A numerical value indicating the number of times the D12 has entered
the error condition "T/S Mis." due to a TOP/SUB mismatch at the output
connectors of the D12 in Dual Channel mode as long as the "TSM
Detection" function was not set to off.
DSP Halt
A numerical value indicating the number of times the D12 has entered
the error condition "DSP Halt" due to a internal fault.
Temp. (Temperature Log)
Proportionate temperature ranges.
These display the proportion of "On Time" the D12 has been operated
within the temperature ranges listed.