8.1 Operation
The chart on the next page illustrates the
corrosive resistance of dierent types of stainless
steel related to NaCl concentration and tempera-
ture.
All critical parts of the APP water pump are made
of Super Duplex.
If the water pump is operated at high salinity,
always ush the water pump with fresh water at
operation stop in order to minimize the risk of
crevice corrosion.
8.2 Storage
Frost protection is required at temperatures
below 2°C. Danfoss recommends to use DOW-
FROST from DOW Chemical Company or Chilsafe
mono propylene glycol from Arco Chemical
Company.
8. Temperature and
corrosion
NaCl vs. temperature
9. Noise level The sound pressure levels, L PA, 1 m
*)
db(A) for
APP 16-22 pumps are typically 82 dB(A) at
60 bar/1500rpm and 84 dB at 80 bar/1500rpm.
Generally, noise will be reduced if speed is
reduced and vice versa. Use exible hoses in
order to minimize vibrations and noise.
Since the pump is typically mounted on a bell
housing or frame, the noise level must be
determined for the complete unit (system). It is
therefore very important that the motor/pump
unit is mounted correctly on a frame with
antivibration isolation to minimize vibrations and
noise.
The noise level is inuenced by:
t The speed of the pump, high rpm create
more noise than low rpm
t Rigid mounting of the pump generates
more noise than exible mounting
t Pipe mounting direct to the pump
increases the noise level compared to a
exible hose
t If using a VFD the motors can produce
higher noise values depending on the
operation point.
t
*) 1 meter from the pump unit surfaces (refer-
ence box) acc. to EN ISO 20361 section 6.2.
Deviation σTOT = ± 1,6 dB(A)
Fluid temperature:
+2° C to +50° C (+35.6° F to 122° F) - dependent
on the NaCl concentration
Ambient temperature:
+2° Cto +50° C (+35.6° F to 122° F)
Storage temperature:
-40° C to +70° C (-40° F to 158° F) – provided
that the pump is drained of uid and stored
”plugged”.