19
180R9265 / IOM APP 16-22 Appendices - v02 / 01.2013
For more information on the importance of
proper ltration, please consult our data sheet
“Filtration” (521B1009), which also will provide
you with an explanation of ltration denitions
and a guidance on how to select the right lter.
Monitoring
It is recommended to continuously monitor the
following conditions:
tlter clogging
tpressure (inlet- and outlet side of the pump)
3. Building up the
pump unit
3.1 Mounting
1. Mount the coupling ush or maximum
1 mm oset from the pump shaft end.
Ensure an air gap between coupling and
pump ange of min. 4 mm (0.16 inch).
2. Mount the bell housing on pump. Secure
nuts with the right torque.
3. Measure the longest distance “A” from top
of bell housing to the button of coupling
claw.
4. Mount the coupling on motor shaft. Ensure
the coupling and motor ange are not in
contact with each other.
5. Measure from motor ange to the top of
the coupling. That measurement “B” shall
be 3-5 mm (0.12 - 0.2 inch) shorter than the
measurement “A”.
6. Adjust respectively, verify the measure-
ment, and secure both couplings with the
right torques on the locking screws (see
coupling operation & mounting instruc-
tion).
7. Mount the elastic gear ring and mount the
bell housing/pump on the motor. After
mounting it must be possible to move the
elastic gear ring 3-5 mm (0.12 - 0.2 inch)
axial “C”. The check can be done through
the inspection hole of bell housing. Secure
ange bolts with the right torque.
A: Elastic coupling
B: Bell housing
C: Motor shaft
D: Pump ange
1: Bolts and nuts: torque 75 Nm ±5 Nm
2: Bolts and nuts: torque 40 Nm ±4 Nm
3: Torque see table below
C
1
2
3
2
1
Thread
size
M4 M5 M6 M8 M10 M12 M16
Torque
(Nm)
1,5 2 4,8 10 17 40 80
Instruction APP pump instruction APP 11-13 and APP 16-22