33
180R9265 / IOM APP 16-22 Appendices - v02 / 01.2013
Instruction Recommended service intervals for APP pumps
3. Appendix 1 Pistons:
The pistons are the heart of the pump regarding
service.
If the pistons break down, the pump will suer a
breakdown.
In case of doubt - the pistons must be replaced.
The pictures below is ment as a guideline for
evaluating the wear of the sliding surface.
Cavitation of the piston shoes.
New inspection is required in 3,000-4,000 hours.
Cavitation of the piston shoes.
All pistons must be replaced within the next
500-1,000 hours.
Cavitation of the piston shoes.
All pistons must be replaced within the next
100-200 hours.
Cavitation of the piston shoes.
All pistons must be replaced immediately.
Abrasive wear of the piston shoes.
All pistons must be replaced immediately.