32
180R9265 / IOM APP 16-22 Appendices - v02 / 01.2013
Instruction Recommended service intervals for APP pumps
Nr. Qty. Description Material Service interval
11Housing, main bearing Duplex, PEEK No need for service
11, 125,
211*
1 Mounting ange/
end ange
Wetted part: Duplex
Dry part: AISI 316L
No wear part
121, 181* 1 Port ange Duplex No wear part
31 1 Swash plate Super Duplex 40,000 hours
66 5/7/9 Piston Super Duplex and PEEK Recommended inspection
on a yearly basis and
evaluated acc. to app. 1
92 1 Valve plated Super Duplex 24,000 hours
91 1 Port plate Super Duplex, PEEK 24,000 hours
61 1 Cylinder barrel Super Duplex 40,000 hours
65 1 Retaining plate Super Duplex 24,000 hours
64 1 Retaining ball Super Duplex 40,000 hours
71 1 Retaining guide Super Duplex 40,000 hours
62 1/4 Spring Duplex 40,000 hours
63 1 Spring guiede Duplex or PP 40,000 hours
142 1 Stop for shaft seal PP No wear part
124, 215* 1 Shaft seal Hasteloy and NBR It is good practice to
change the seal after each
disassembly of the pump
125 1 Cover/ange for
shaft seal
Super Duplex No wear part
93 5/7/9 Back-up ring Teon 24,000 hours
* O-ring (overall) NBR 24,000 hours
* Screw (overall) AISI 316 No wear part
* Pin (overall) AISI 316, Duplex or PEEK No wear part
152 1 Valve cone (ushing valve) Duplex or PEEK 40,000 hours
3, 129* 2 Bleeding screw Duplex No wear part
67 1 Parallel key AISI 302 40,000 hours
1. General information This guideline provides information on the
recommended service intervals. The recommen-
dation is based upon good engineering practice
and on experience gained from operation even
under extreme conditions.
The recommendation is for guidance only.
2. Design/features
Danfoss APP pumps are designed for long
operation and low maintenance and life cycle
costs.
Danfoss guarantees 8,000 hours service free
operation, however max. 18 months from date of
production. After 8,000 operation hours it is
recommended to inspect the pump and replace
worn parts, if any.
If the Danfoss recommendations concerning
system-design (see our data sheet) are not
followed, the service life of the APP pumps might
be aected.
The recommended service intervals on the
dierent parts in the APP pumps appear from the
table below:
1. General information
2. Design/features
3. Appendix 1
Recommended service
intervals for APP pumps
(180R9199)
Table of Contents
* depends on pump size

Table of Contents

Other manuals for Danfoss APP series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss APP series and is the answer not in the manual?

Danfoss APP series Specifications

General IconGeneral
BrandDanfoss
ModelAPP series
CategoryWater Pump
LanguageEnglish

Related product manuals