EasyManua.ls Logo

Danfoss D1 Series - TPSN (Power Control + Pressure Compensated Control + Load Sensing Control)

Danfoss D1 Series
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TPSN (Power Control + Pressure Compensated Control + Load Sensing Control)
D1P 130/145+TPSN
X
MB
B
(1)
P400251
Vg min
Vg max
L3
S M4 L1 L2
D1P 193/260+TPSN
*Control oil filter is optional
P400080
X
Vg min
CW
Vg max
MB
B
L3
S M4 L1 L2
(1)
Power Control (T) Principle
The power control regulates the displacement of the pump depending on the working pressure so that a
given drive power is not exceeded at constant drive speed, this function can prevent engine stall or
protect electric generator.
P
B
= working pressure
P
B
• V
g
= C V
g
= displacement
C = constant
The precise control with a hyperbolic control characteristic, provides an optimum utilization of available
power.
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Operation
©
Danfoss | July 2019 L1527453 | AX00000292en-CN0201 | 15