EasyManua.ls Logo

Danfoss D1 Series - Solenoid Specification

Danfoss D1 Series
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
W
Warning
Do not actuate the MOR unless the machine is in a “SAFE” mode. Unintended MOR operation will cause
the pump to go into stroke, use only for diagnosis purposes.
Solenoid Specification
Technical data - Solenoid
Voltage
24V (±20%)
Start current at Vg min.
200 mA
End Current at Vg max.
600 mA
Maximum current
770 mA
Coil Resistance @ 20 °C [70 °F]
22.7 Ω
PWM Range
70~200 Hz
PWM Frequency (preferred)
*
100 Hz
IP Rating (IEC 60 529) + DIN 40 050, part 9
IP 67
IP Rating (IEC 60 529) + DIN 40 050, part 9 with
mating connector
IP 69K
*
PWM signal required for optimum control performance
Mating connector for Solenoid
Description Ordering Number Quantity
Mating Connector DEUTSCH DT06-2S 1
Wedge Lock DEUTSCH W2S 1
Socket contact (16 and 18 AWG) DEUTSCH 0462-201-16141 2
Danfoss mating connector kit K29657 1
The mating connector is not included in the delivery contents, this can be delivered by Danfoss on request.
Compatible PLUS+1
®
controllers(see below):
MC012 L1301095
MC024 L1315302
MC038 11051653
MC050 L1301752
MC088 11006645
For further information: please visit: http://www.danfoss.com/Products/MobileElectronics/index.htm
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Operation
©
Danfoss | July 2019 L1527453 | AX00000292en-CN0201 | 19