Plug and fitting installation
If any plugs or fittings are removed from the unit during service, install and torque as indicated. The
following drawings are in generic configurations to show item number for wrench size and torque
reference.
D1P 193 TPE2 control plug fittings
G235
G250
F140
F150
G225
F160
G240
G130
G140
Plug fitting reference
Item Description Wrench size Torque
F160 Drain port L1 (M33 x 2) 17 mm hex 68.4-83.6 Nm
G225 Outlet pressure test port MB (M12 x 1.5) 6 mm hex 22.5-27.5 Nm
G230 Bias orifice 3 mm hex 3.6-4.4 Nm
G240 Bias orifice plug (M8 x 1) 4 mm hex 9.9-12.1 Nm
G235 Servo pressure test port M4 (M12 x 1.5) 6 mm hex 22.5-27.5 Nm
G140 Servo orifice 4 mm 3.6-4.4 Nm
F140 Drain port L3 (M33 x 2) 17 mm hex 68.4-83.6 Nm
F150 Drain port L2 (M33 x 2) 17 mm hex 68.4-83.6 Nm
G250 Servo orifice plug (M12 x 1.5) 6 mm hex 22.5-27.5 Nm
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Minor repairs
56 |
©
Danfoss | July 2019 L1527453 | AX00000292en-CN0201