Flammable Cleaning Solvents
Some cleaning solvents are flammable.
Do not use cleaning solvents in an area where a source of ignition may be present to avoid possible fire.
Fluid Under Pressure
Escaping hydraulic fluid under pressure can have sufficient force to penetrate your skin causing serious
injury and/or infection. This fluid may also be hot enough to cause burns.
Relieve pressure in the system before removing hoses, fittings, gauges, or components. Never use your
hand or any other body part to check for leaks in a pressurized line. Use caution when dealing with
hydraulic fluid under pressure. Seek medical attention immediately if you are cut by hydraulic fluid.
Personal Safety
Protect yourself from injury whenever servicing a hydraulic system.
Use proper safety equipment, including safety glasses, at all times.
Symbols used in Danfoss literature
WARNING may result in injury Tip, helpful suggestion
CAUTION may result in damage to product or
property
Lubricate with hydraulic fluid
Reusable part Apply grease / petroleum jelly
Non-reusable part, use a new part Apply locking compound
Non-removable item Inspect for wear or damage
Option - either part may exist Clean area or part
Superseded - parts are not interchangeable Be careful not to scratch or damage
Measurement required Note correct orientation
Flatness specification Mark orientation for reinstallation
Parallelism specification Torque specification
External hex head Press in - press fit
Internal hex head Pull out with tool – press fit
Torx head Cover splines with installation sleeve
O-ring boss port Pressure measurement/gauge location or
specification
The symbols above appear in the illustrations and text of this manual. They are intended to communicate
helpful information at the point where it is most useful to the reader. In most instances, the appearance
of the symbol itself denotes its meaning. The legend above defines each symbol and explains its purpose.
D1 pumps design
Danfoss D1 high power open circuit piston pumps convert input torque into hydraulic power. Rotational
force is transmitted through the input shaft to the cylinder block. The input shaft is supported by roller
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Introduction
6 |
©
Danfoss | July 2019 L1527453 | AX00000292en-CN0201

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss D1 Series and is the answer not in the manual?

Danfoss D1 Series Specifications

General IconGeneral
BrandDanfoss
ModelD1 Series
CategoryWater Pump
LanguageEnglish

Related product manuals