Danfoss ECtemp Next Plus
13Installation Guide
It would also be possible to use only one temperature
sensor. However, this option is not recommendable as this
cause an increased risk of overheating of the oor.
Extending maximum oor temperature and Setting into
room only mode – See point 4.9 and 4.10.
IMPORTANT: When the thermostat is used to control a
oor heating element in connection with a wooden oor or
similar material, always use a oor sensor and never set the
maximum oor temperature to more than 35 ° C.
Thermal
resistance
[m
2
K/W]
Examples of
Flooring
Details Approximate
setting for
25˚C oor
temperature
0.05 8 mm HDF
based lami-
nate
>800 kg/m
3
28˚C
0.10 14 mm beech
parquet
650 - 800
kg/m
3
31˚C
0.13 22 mm solid
oak plank
>800 kg/m
3
32˚C
< 0.17 Max. carpet
thickness suit-
able for oor
heating
acc. to EN
1307
34˚C
0.18 22 mm solid
for planks
450 - 650
kg/m
3
35˚C