Danfoss ECtemp Next Plus
Installation Guide16
Adjust Maximum Floor temperature according to need up
to 45°C
Power ON
Press M button for 6 seconds
Select P03 (Table in 4.2): raise oor temperature limitation
higher than 35°C by using the >
4�11 Table for 4�9 Change to Room control only and
4�10 Extending Maximum Floor temperature
limitations to 45°C
No. Function Setting Factory default
Danfoss ECtemp™
Next Plus
P01 Room Sensor
Calibration
Oset:-10˚C to
+10˚C
0˚C
P02 Floor Sensor
Calibration
Oset:-10˚C to
+10˚C
0˚C
P03 Maximum
Room Temp.
Limitation
5-35˚C(Active in
Temperature Control
Mode 01)
35˚C
P04 Minimum
Room Temp.
Limitation
5-35˚C(Active in
Temperature Control
Mode 01)
5˚C
P05 Maximum
Room Temp.
Limitation
5-35˚C(Active in
Temperature Control
Mode 02)
35˚C