Danfoss ECtemp Next Plus
Installation Guide6
2 Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable height on the wall
(typically 80-170cm.).
The thermostat should not be placed in wet rooms.
Place it in an adjacent room and use oor sensor
only. Always place the thermostat according to local
regulation on IP classes and use oor sensor only.
Do not place the thermostat on the inner side of an
exterior wall.
Always install the thermostat at least 50 cm. from
windows and doors.
Do not place the thermostat in a way that it will be
exposed to direct sunlight.
Note: A oor sensor enables a more accurate
temperature control and is recommended in all oor
heating applications and mandatory under wooden
oors to reduce the risk of over-heating the oor.