Page #7 background imageLoading...
Page #7 background image
Danfoss ECtemp Next Plus
7Installation Guide
Place the oor sensor in a conduit in an appropriate place
where it is not exposed to sunlight or draft from door
openings.
Equally distant and >2cm from two heating cables.
The conduit should be ush with the oor surface -
countersink the conduit if necessary.
Route the conduit to the connection box.
The bending radius of the conduit must be min 50mm.
Connect the thermostat according to the connection
diagram.
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by using a
separate connector.
Note: Always install the oor sensor in a conduit in the
oor.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ECtemp Next Plus and is the answer not in the manual?

Danfoss ECtemp Next Plus Specifications

General IconGeneral
Voltage220 - 240 V
Temperature range (T-T)-10 - 60 °C
Temperature control range5 - 45 °C
Power sourceAC
Power consumption (standby)2 W
Product colorWhite
Memory function-
Housing materialPlastic
Smart thermostatYes
International Protection (IP) codeIP30
Weight and Dimensions IconWeight and Dimensions
Depth16 mm
Width86 mm