Danfoss ECtemp Next Plus
17Installation Guide
P06 Minimum
Room Temp.
Limitation
5-35˚C(Active in
Temperature Control
Mode 02)
5˚C
P07 Setting range
extension for
P06, P07, P08
01: Max. 35˚C, 02:
Max. 45˚C
01
P08 Only room
temperature
control
01: Enable, 02:
Disable
02
5 Error Codes
E1 Room sensor failure
E2 Floor sensor failure
EE EEPROM failure
Lo Temperature lower than 0˚C
Hi Temperature higher than 5˚C
All relay output will be turned o in all cases.