Danfoss ECtemp Next Plus
Installation Guide4
Ambient temperature -10°C to +60°C
Frost protection temperature 5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C.
Floor temperature: Max. 35°C
is default.
Sensor failure monitoring The thermostat has a built-in
monitoring circuit, which will
switch o the heating if the
sensor is disconnected or short-
circuited
Cable specication max. 1x4 mm
2
or 2x2,5 mm
2
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20°C to +65°C
IP class 30
Protection class Class II -
Dimensions 86 x 86 x 16/40.5 mm
(in-wall depth: 24.5 mm)
Weight 103 g
Electrical safety and Electro-Magnetic Compatibility for
this product is covered by the compliance with the EN/IEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ECtemp Next Plus and is the answer not in the manual?

Danfoss ECtemp Next Plus Specifications

General IconGeneral
Voltage220 - 240 V
Temperature range (T-T)-10 - 60 °C
Temperature control range5 - 45 °C
Power sourceAC
Power consumption (standby)2 W
Product colorWhite
Memory function-
Housing materialPlastic
Smart thermostatYes
International Protection (IP) codeIP30
Weight and Dimensions IconWeight and Dimensions
Depth16 mm