FC 300 Instruction Manual
How to Program
" 16-** D ata readouts
Par.
No. #
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
16-0* General status
16-00 Control Word 0 All set-ups FALSE 0 V2
16-01 Reference [Unit] 0.000 Unit All set-ups FALSE -3 Int32
16-02 Reference % 0.0 % All set-ups FALSE -1 Int16
16-03 Status word 0 All set-ups FALSE 0 V2
16-05 Main actual value [%] 0 All set-ups FALSE 0 N 2
16-1* Motor status
16-10 Power [kW] 0.0 kW All set-ups FALSE 2 U int32
16-11 Power [hp] 0.00 hp All set-ups FALSE -2 U int32
16-12 Motor voltage 0.0 V All set-ups FA LSE -1 Uint16
16-13 Frequency 0.0 Hz All set-ups FALSE -1 Uint16
16-14 Motor current 0.00 A All set-ups FALSE -2 Uint32
16-16 Torque 0.0 Nm All set-ups FALSE -1 Int16
16-17 Spe ed [RPM] 0 RPM All set-ups FA LSE 67 Int32
16-18 Motor therm al 0 % All se t-ups FALSE 0 Uint8
16-3* Drive status
16-30 DC link Voltage 0 V All set-ups FALSE 0 Uint16
16-32 Brake energy /s 0 .0 HP All set-ups FA LSE 0 Uint32
16-33 Brake energy /2 min 0.0 HP All set-ups FALSE 0 Uint32
16-34 He atsink temp. 0 °C All se t-ups FALSE 100 Uint8
16-35 Inverter thermal 0 % All se t-ups FALSE 0 Uint8
16-36 InomVLT Drive dependent All set-ups FALSE -2 Uint16
16-37 ImaxVLT Drive dependent All set-ups FALSE -2 Uint16
16-38 SL controller state 0 All set-ups FALSE 0 Uint8
16-39 Controlcard temp. 0 °C All set-ups FALSE 100 Uint8
16-5* Ref. & feedb.
16-50 External reference 0.0 All set-ups FALSE -1 Int16
16-51 Pulse refere nce 0.0 All set-ups FALSE -1 Uint32
16-52 Feedback [Unit] 0.000 All set-ups FALSE -3 I nt32
16-6* Inputs & outputs
16-60 Digital input 0 All set-ups FALSE 0 Uint16
16-61 Terminal 53 switch setting [0] Current All set-ups FALSE - Uint8
16-62 Analog input 53 0.000 All se t-ups FALSE -3 Int32
16-63 Terminal 54 switch setting [0] Current All set-ups FALSE - Uint8
16-64 Analog input 54 0.000 All se t-ups FALSE -3 Int32
16-65 Analog output 42 [mA] 0.000 All set-ups FALSE -3 Int16
16-66 Digital output [bin] 0 All set-ups FALSE 0 Int16
16-67 Freq. input #29 [Hz] 0 All set-ups FALSE 0 Int32
16-68 Freq. input #33 [Hz] 0 All set-ups FALSE 0 Int32
16-69 Pulse output #27 [Hz] 0 All set-ups FALSE 0 Int32
16-70 Pulse output #29 [Hz] 0 All set-ups FALSE 0 Int32
16-8* Fieldbus & FC port
16-80 Fieldbus CTW 1 0 All set-ups FA LSE 0 V2
16-82 Fieldbus REF 1 0 All set-ups FALSE 0 N2
16-84 Com m. option STW 0 All set-ups FALSE 0 V2
16-85 FC port CTW 1 0 All set-ups FALSE 0 V2
16-86 FC port REF 1 0 All set-ups FALSE 0 N 2
16-9* Diagnosis Readout
16-90 Alarm word 0 All se t-ups FALSE 0 Uint32
16-92 Warning word 0 All-setups FALSE 0 Uint32
16-94 Extended status word 0 All-setups FALSE 0 Uint32
*
default setting ()display text []value for use in communication via serial communication port
58
MG.33.A
4.22 - VLT is a registered Danfoss trademark

Other manuals for Danfoss FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss FC 302 and is the answer not in the manual?

Danfoss FC 302 Specifications

General IconGeneral
ModelFC 302
BrandDanfoss
Protection ClassIP20
Communication InterfaceRS485, PROFIBUS
Relative Humidity5-95% (non-condensing)
Ambient Temperature-10 to 45 / 50 °C (depending on enclosure)
Storage Temperature-25 to 65°C

Related product manuals