Nomen-
clature
Parameter
FLX series
56789
Max. short-circuit
current DC (at STC) 13.5 A per PV input
Min. on grid power 20 W
Efficiency
Max. efficiency - 97.8% - 97.9% -
Euro efficiency, V at
dc,r
- 96.5% - 97.0% -
Other
Dimensions (H, W,
D), inverter / incl.
packaging
667 x 500 x 233 mm / 774 x 570 x 356 mm
Mounting
recommendation
Mounting plate
Weight, inverter /
incl. packaging
38 kg / 44 kg
Acoustic noise level
4
-
MPP trackers 2
Operation
temperature range
-25..60 °C
Nom. temperature
range
-25..45 °C
Storage temperature
-25..60 °C
Overload operation Change of operating point
Overvoltage
categories
Grid: OVC III
PV: OVC II
Table 5.1 Specifications
1)
At rated grid voltage (V
ac,r
), Cos(phi)=1.
2)
To utilise the full range, asymmetrical layouts must be considered
including start-up voltage for at least 1 string. Achieving nominal
power will depend on configuration.
3)
At symmetric input configuration.
4)
SPL (Sound Pressure Level) at 1 m under normal operating
conditions. Measured at 25 °C.
Nomen-
clature
Parameter
FLX series
10 12.5 15 17
AC
|S| Rated apparent
power
10 kVA 12.5 kVA 15 kVA 17 kVA
P
ac,r
Rated active power
1)
10 kW 12.5 kW 15 kW 17k W
Active power at
cos(phi)=0.95
9.5 kW 11.9 kW 14.3 kW 16.2 kW
Active power at
cos(phi)=0.90
9.0 kW 11.3 kW 13.5 kW 15.3 kW
Reactive power
range
0 - 6.0 kVAr 0-7.5 kVAr 0-9.0 kVAr 0-10.2 kVAr
V
ac,r
Nominal AC voltage
(AC voltage range)
3P+N+PE - 230/400 V (+/- 20 %)
Rated current AC 3 x 14.5 A 3 x 18.2 A 3 x 21.7 A 3 x 24.7 A
Technical Data
L00410568-02_02 / Rev. date: 2013-12-10 35
5