VFD500 high performance vector control frequency inverter user manual Chapter 5 function code table
P11.12
Rotor resistor of
Asychronous motor
Unit:0.001Ω(P11.02<30kW)#
Unit:0.01mΩ(P11.02>=30kW)
Depend
P11.13
Leakage inductance of
Asychronous motor
Unit:0.01mH(P11.02<30kW)#
Unit:0.001mH(P11.02>=30kW)
Depend
P11.14
Mutual inductance of
Asynchronous motor
Unit:0.1mH(P11.02<30kW)#
Unit:0.01mH(P11.02>=30kW)
Depend
P11.15
No-load excitation current of
Asynchronous motor
Unit:0.01AP11.02(<30kW)#
Unit:0.1A(P11.02>=30kW)
Depend
P11.16
Excitation saturation factor 1
At non rated-excitation status
1.100
P11.17
Excitation saturation factor 2
At non rated-excitation status
0.900
P11.18
Excitation saturation factor3
At non rated-excitation status
0.800