EasyManuals Logo

Danfoss vlt aqua User Manual

Danfoss vlt aqua
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
4.1.14 PC Software tools
PC-based Configuration Tool MCT 10
All adjustable frequency drives are equipped with a serial communication port. Danfoss provides a PC tool for communication between the PC and the
adjustable frequency drive, PC-based Configuration Tool MCT 10. Please check the section on
Available Literature
for detailed information on this tool.
MCT 10 Set-up Software
MCT 10 has been designed as an easy to use interactive tool for setting parameters in our adjustable frequency drives. The software can be downloaded
from the Danfoss internet site
http://www.
Danfoss
.com/BusinessAreas/DrivesSolutions/Softwaredownload/DDPC+Software+Program.htm
.
The xMCT 10 Set-up software will be useful for:
Planning a communication network off-line. MCT 10 contains a complete adjustable frequency drive database
Commissioning adjustable frequency drives on-line.
Saving settings for all adjustable frequency drives.
Replacing an adjustable frequency drive in a network.
Simple and accurate documentation of adjustable frequency drive settings after commissioning.
Expanding an existing network.
Adjustable frequency drives developed in the future will be fully supported.
MCT 10 set-up software supports Profibus DP-V1 via a master class 2 connection. This makes it possible to access on-line read/write parameters in an
adjustable frequency drive via the Profibus network. This will eliminate the need for an extra communication network.
Save Adjustable Frequency Drive Settings:
1. Connect a PC to the unit via the USB COM port. (Note: Use a PC that is isolated from the line power, in conjunction with the USB port. Failure
to do so may damage equipment.)
2. Open MCT 10 Set-up Software
3. Choose “Read from drive”.
4. Choose “Save as”.
All parameters are now stored on the PC.
Load Adjustable Frequency Drive Settings:
1. Connect a PC to the adjustable frequency drive via the USB com port
2. Open MCT 10 Set-up software
3. Choose “Open”– stored files will be shown.
4. Open the appropriate file.
5. Choose “Write to drive.”
All parameter settings are now transferred to the adjustable frequency drive.
A separate manual forMCT 10 Set-up Software is available:
MG.10.Rx.yy
.
The MCT 10 Set-up Software Modules
The following modules are included in the software package:
4 How to operate the adjustable frequency
drive
VLT AQUA High Power Instruction Manual
4-14
MG.20.P3.22 - VLT
®
is a registered Danfoss trademark
4

Other manuals for Danfoss vlt aqua

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt aqua and is the answer not in the manual?

Danfoss vlt aqua Specifications

General IconGeneral
Supply Voltage200-240V, 380-500V, 525-600V
EnclosureIP20
FeaturesEnergy optimization
ApprovalsCE, UL, cUL
Input Voltage Range200-240V, 380-500V, 525-600V
Output Voltage Range0 to supply voltage
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short circuit, Ground fault
Communication InterfacesPROFIBUS
Cooling MethodAir-cooled