13-10 Comparator Operand
Array [6]
Option: Function:
[13] Analog input
AI54
[13] Analog input AI54 Expressed as a
percentage.
[14] Analog input
AIFB10
[14] Analog input AIFB10 [V]. AIFB10 is
internal 10 V supply.
[15] Analog input
AIS24V
[15] Analog input AIS24V [V] Analog
input AICCT [17] [°]. AIS24V is switch
mode power supply: SMPS 24V.
[17] Analog input
AICCT
[17] Analog input AICCT [°]. AICCT is
control card temperature.
[18] Pulse input FI29
[18] Pulse input FI29 Expressed as a
percentage.
[19] Pulse input FI33
[19] Pulse input FI33 Expressed as a
percentage.
[20] Alarm number
[20] Alarm number The error number.
[21] Warning number
[22] Analog input
x30 11
[23] Analog input
x30 12
[30] Counter A
[30] Counter A Number of counts
[31] Counter B
[31] Counter B Number of counts
[50] FALSE
[50] False Enters the fixed value of false
in the comparator.
[51] TRUE
[51] True Enters the fixed value of true
in the comparator.
[52] Control ready
[52] Control ready The control board
receives supply voltage
[53] Drive ready
[53] Drive ready The frequency converter
is ready for operation and applies a
supply signal on the control board.
[54] Running
[54] Running The motor is running.
[55] Reversing
[55] Reversing The output is high when
the frequency converter is running
counter clockwise (the logical product of
the status bits “running” AND “reverse”)
[56] In range
[56] In range The motor is running
within the programmed current and
speed ranges set in 4-50 Warning
Current Low to 4-53 Warning Speed High.
[60] On reference
[60] On reference The motor is running
on reference.
[61] Below reference,
low
[61] Below reference, low The motor is
running below the value given in
4-54 Warning Reference Low
13-10 Comparator Operand
Array [6]
Option: Function:
[62] Above ref, high
[62] Above reference, high The motor is
running above the value given in
4-55 Warning Reference High
[65] Torque limit
[65] Torque limit The torque limit, set in
4-16 Torque Limit Motor Mode or
4-17 Torque Limit Generator Mode, has
been exceeded.
[66] Current limit
[66] Current limit The motor current
limit, set in 4-18 Current Limit, has been
exceeded.
[67] Out of current
range
[67] Out of current range The motor
current is outside the range set in
4-18 Current Limit.
[68] Below I low
[68] Below I low The motor current is
lower than set in 4-50 Warning Current
Low.
[69] Above I high
[69] Above I high The motor current is
higher than set in 4-51 Warning Current
High.
[70] Out of speed
range
[70] Out of speed range The speed is
outside the range set in 4-52 Warning
Speed Low and 4-53 Warning Speed High.
[71] Below speed low
[71] Below speed low The output speed
is lower than the setting in
4-52 Warning Speed Low.
[72] Above speed
high
[72] Above speed high The output speed
is higher than the setting in
4-53 Warning Speed High.
[75] Out of feedb.
range
[75] Out of feedb. Range The feedback is
outside the range set in 4-56 Warning
Feedback Low and 4-57 Warning
Feedback High.
[76] Below feedb.
low
[76] Below feedb. Low The feedback is
below the limit set in 4-56 Warning
Feedback Low.
[77] Above feedb.
high
[77] Above feedb. High The feedback is
above the limit set in 4-57 Warning
Feedback High.
[80] Thermal warning
[80] Thermal warning The thermal
warning turns on when the temperature
exceeds the limit in the motor, the
frequency converter, the brake resistor
or thermistor.
[82] Mains out of
range
[82] Mains out of range The mains
voltage is outside the specified voltage
range.
[85] Warning
[85] Warning A warning is active.
[86] Alarm (trip)
[86] Alarm (trip) A (trip) alarm is active.