1-10 Motor Construction AC motor PM Non salient Motor
1-25 Motor Nominal Speed + + + +
1-26 Motor Cont. Rated Torque - - - - + + +
1-29 Automatic Motor Adaptation
(AMA)
+ + + +
1-30 Stator Resistance (Rs) + + + + +
1-31 Rotor Resistance (Rr)
-
+
see 5)
+ +
1-33 Stator Leakage Reactance (X1) + + + + +
1-34 Rotor Leakage Reactance (X2)
-
+
see 5)
+ +
1-35 Main Reactance (Xh) + + + + +
1-36 Iron Loss Resistance (Rfe) - - + + - - -
1-37 d-axis Inductance (Ld) - - - - + +
1-39 Motor Poles + + + +
1-40 Back EMF at 1000 RPM - - - - + + +
1-41 Motor Angle Offset - - - - +
Table 4.3
1) Constant torque
2) Variable torque
3) AEO
4) Constant power
5) Used in flystart