1-10 Motor Construction AC motor PM Non salient Motor
1-01 Motor Control Principle
U/f mode
VVC
plus
Flux sensorless
Flux w/ motor
feedback
U/f mode
Flux
sensorless
Flux w/
motor
feedback
1-50 Motor Magnetisation at Zero
Speed
- + - - - - -
1-51 Min Speed Normal
Magnetising [RPM](Par. 002 =
rmp)
- + - - - - -
1-52 Min Speed Normal
Magnetising [Hz](Par. 002 = Hz)
- + - - - - -
1-53 Model Shift Frequency - - + + - + +
1-54 Voltage reduction in
fieldweakening
- -
+
see 6)
+ - - -
1-55 U/f Characteristic - U + - - - + - -
1-56 U/f Characteristic - F + - - - + - -
1-58 Flystart Test Pulses Current - + - - - - -
1-59 Flystart Test Pulses
Frequency
- + - - - - -
1-60 Low Speed Load Compen-
sation
- + - - - - -
1-61 High Speed Load Compen-
sation
- + - - - - -
1-62 Slip Compensation
-
+
see 7)
+ - - - -
1-63 Slip Compensation Time
Constant
+
see 8)
+
+
see 8)
-
+
see 8)
+
see 8)
-
1-64 Resonance Dampening + + + - + + -
1-65 Resonance Dampening Time
Constant
+ + + - + + -
1-66 Min. Current at Low Speed - - + + - + +
1-67 Load Type - - + - - - -
1-68 Minimum Inertia - - + - - - -
1-69 Maximum Inertia - - + - - - -
1-71 Start Delay + + + + + + +
1-72 Start Function + + + + + + +
1-73 Flying Start - + + + - - -
1-74 Start Speed [RPM](Par. 002 =
rmp)
- + - - - - -
1-75 Start Speed [Hz](Par. 002 =
Hz)
- + - - - - -
1-76 Start Current - + - - - - -
Table 4.4
6) Used when 1-03 Torque Characteristics is constant power
7) Not used when 1-03 Torque Characteristics = VT
8) Part of resonance damping
Parameter Lists
VLT
®
AutomationDrive Programmming Guide
162 MG33ME02 - VLT
®
is a registered Danfoss trademark
44