5.2.10 9-** PROFIdrive
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
9-00 Setpoint 0 N/A All set-ups TRUE 0 Uint16
9-07 Actual Value 0 N/A All set-ups FALSE 0 Uint16
9-15 PCD Write Conguration ExpressionLimit 1 set-up TRUE - Uint16
9-16 PCD Read Conguration ExpressionLimit 1 set-up TRUE - Uint16
9-18 Node Address 126 N/A 1 set-up TRUE 0 Uint8
9-19 Drive Unit System Number 1037 N/A All set-ups TRUE 0 Uint16
9-22 Telegram Selection [100] None 1 set-up TRUE - Uint8
9-23 Parameters for Signals 0 All set-ups TRUE - Uint16
9-27 Parameter Edit [1] Enabled 1 set-up FALSE - Uint16
9-28 Process Control
[1] Enable cyclic
master 1 set-up FALSE - Uint8
9-44 Fault Message Counter 0 N/A All set-ups TRUE 0 Uint16
9-45 Fault Code 0 N/A All set-ups TRUE 0 Uint16
9-47 Fault Number 0 N/A All set-ups TRUE 0 Uint16
9-52 Fault Situation Counter 0 N/A All set-ups TRUE 0 Uint16
9-53 Probus Warning Word 0 N/A All set-ups TRUE 0 V2
9-63 Actual Baud Rate
[255] No baudrate
found All set-ups TRUE - Uint8
9-64 Device Identication 0 N/A All set-ups TRUE 0 Uint16
9-65 Prole Number 0 N/A All set-ups TRUE 0 OctStr[2]
9-67 Control Word 1 0 N/A All set-ups TRUE 0 V2
9-68 Status Word 1 0 N/A All set-ups TRUE 0 V2
9-70 Edit Set-up [9] Active Set-up 1 set-up TRUE - Uint8
9-71 Probus Save Data Values [0] O All set-ups TRUE - Uint8
9-72 ProbusDriveReset [0] No action 1 set-up FALSE - Uint8
9-75 DO Identication 0 N/A All set-ups TRUE 0 Uint16
9-80 Dened Parameters (1) 0 N/A All set-ups FALSE 0 Uint16
9-81 Dened Parameters (2) 0 N/A All set-ups FALSE 0 Uint16
9-82 Dened Parameters (3) 0 N/A All set-ups FALSE 0 Uint16
9-83 Dened Parameters (4) 0 N/A All set-ups FALSE 0 Uint16
9-84 Dened Parameters (5) 0 N/A All set-ups FALSE 0 Uint16
9-85 Dened Parameters (6) 0 N/A All set-ups FALSE 0 Uint16
9-90 Changed Parameters (1) 0 N/A All set-ups FALSE 0 Uint16
9-91 Changed Parameters (2) 0 N/A All set-ups FALSE 0 Uint16
9-92 Changed Parameters (3) 0 N/A All set-ups FALSE 0 Uint16
9-93 Changed Parameters (4) 0 N/A All set-ups FALSE 0 Uint16
9-94 Changed Parameters (5) 0 N/A All set-ups FALSE 0 Uint16
9-99 Probus Revision Counter 0 N/A All set-ups TRUE 0 Uint16
5.2.11 10-** CAN Fieldbus
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
10-0* Common Settings
10-01 Baud Rate Select [20] 125 Kbps 1 set-up TRUE - Uint8
10-02 Node ID 127 N/A 1 set-up TRUE 0 Uint8
10-05 Readout Transmit Error Counter 0 N/A All set-ups TRUE 0 Uint8
10-06 Readout Receive Error Counter 0 N/A All set-ups TRUE 0 Uint8
10-3* Parameter Access
10-31 Store Data Values [0] O All set-ups TRUE - uint8
Parameter Lists
VLT
®
Midi Drive FC 280
124 Danfoss A/S © 12/2015 All rights reserved. MG07C102