Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state once the 
state is entered. The range for this setting is from 1 to 255 seconds in 1-second incre-
ments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 
0
05, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming 
Mo
de.
4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING on 
page 93.
5. Scan the appropriate two digits from the keypad in 
Appendix D, that represent the 
duration which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this fea-
ture.
Table 17 Scanning Active Time Setting Examples
NOTE: If you make a mistake before the last character, scan the CANCEL 
bar code to abort and not save the entry string. You can then start again at 
the beginning.
STEP
ACTION EXAMPLES
1 Desired Setting
1 Second
90 Sec.
(1.5 min.)
180 Sec.
(3 min.)
255 Seconds 
(4.25 min.)
2 Pad leading zero(es)
001 090 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT SCANNING ACTIVE TIME SETTING
5
Scan three characters from 
Appendix D
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE