ENTER/EXIT PROGRAMMING MODE RS-232 INTERFACE
36
   GRYPHON™ I GD/GBT/GM4200
Data Bits
This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit 
ASCII protocol for sending and receiving data.
Stop Bits
The stop bit(s) at the end of each transmitted character marks the end of transmission 
of one character and prepares the receiving device for the next character in the serial 
data stream. The number of stop bits selected (one or two) depends on the number the 
receiving terminal is programmed to accommodate. Set the number of stop bits to 
match host device requirements..
$CR2DA00
7 Data Bits
8 Data Bits
$CR2DA01
NOTE: Handheld and Cradle models support the 8-bit ASCII protocol. 
The 7-bit ASCII protocol support is subject to specific firmware release. 
If the setting is not supported, the scanner will emit three short beeps 
upon scanning the label.
$CR2ST00
1 Stop  Bit
2 Stop  Bits