Page #45 background image
Error Codes
Quick Reference Guide 37
Error Codes
Upon startup, if the reader sounds a long tone, this means the
reader has not passed its automatic Selftest and has entered
FRU (Field Replaceable Unit) isolation mode. If the reader is
reset, the sequence will be repeated. The following table
describes the LED flashes/beep codes associated with an
error found.
Base Station Indications
Number of LED
Flashes/
Beeps
Error
Corrective
Action
1 Configuration
Contact
Helpdesk
for assis-
tance
2Interface PCB
6 Digital PCB
12 Imager
Indication LEDs
Power-up Complete Yellow LED on
Reader Disabled by the HOST or
the communication with HOST is
not established
Yellow LED blinking ~1Hz
Data/labels are transmitted to
the HOST
Yellow LEDs turned off for
100mSec
Programming Mode Yellow LED blinks quickly
Configuration alignment with the
HH is in progress
Red LED blinks quickly
Battery charger in progress Red LED on
Battery charger complete Green LED on
Battery charger error
Green LED and Red LEDs
blink alternatively ~1Hz
No HH is placed on the cradle Red and Green LEDs off

Other manuals for Datalogic QuickScan QBT2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QBT2400 and is the answer not in the manual?

Datalogic QuickScan QBT2400 Specifications

General IconGeneral
ConnectivityBluetooth
Battery TypeLithium-Ion
Battery Capacity1400 mAh
IP RatingIP42
Print Contrast Ratio (Minimum)25%
Interfaces SupportedUSB, RS-232, Keyboard Wedge
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Drop ResistanceWithstands drops from 1.5 m / 5.0 ft
Radio Range (Open Air)100 m
TypeHandheld
Scan Rate60 frames per second
Resolution0.1 mm
Humidity5 to 95% non-condensing
Light SourceRed LED
Supported Barcodes1D / 2D and postal codes