155
OTHER CONTROLS
Defaults
Scanner
Type
Code
Parameter
Description
I.D.# Accept. Input
Min
Max
Factory
Laser
2D Imager
Enter 1 for On and 0 for Off
Enable Label
Programming
Enables/disables
the ability to
perform label
programming.
FF00 On or Off On On On √ √
Send
Symbology
Identifiers
Specifies the
symbology
identifier (if any)
that is sent by the
decoder when
parameter Send
Code ID (Index
0025) is set to 3.
ASCII code zero
(null) used to
indicate an
identifier not to be
sent for the
symbology.
0025
Select symbology
identifier to transmit
immediately preceding
scanned data:
0=None
1=DLM identifier before
label: <ID> " " <data>
2=AIM identifier before
label: "]" <ID>
<modifier> <data>
3=User defined identifier
before label: <ID>
<data>
4=DLM identifier after
label: <data> " " <ID>
5=AIM identifier after
label: <data> "]" <ID>
<modifier>
6=User defined identifier
after label: <data> <ID>
00 01 00 √ √
Label Prefix
Character string
sent immediately
prior to
symbology
identifier
(0=None).
0026
A string of Unicode
characters.
NUL NUL NUL √ √
Label Suffix*
Character string
sent immediately
after final
character in data
(0=None).
0027
A string of Unicode
characters.
CR+LF CR+LF CR+LF √ √
Label
Separator
Character string
sent after each
string in a sample
where multiple
strings exist.
0028
Any single ASCII
character (00 = Off).
CR CR CR √ √
Only a single character can be programmed with a programming label; strings can only be programmed in the
Decoding control panel applet.