Code 128 Enter/Exit Programming Mode
Product Reference Guide  
          151
Code 128 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 128 
symbology.
Variable Length: 
For variable length decoding, a minimum and maximum length may be set.
Fixed Length: 
For fixed length decoding, two different lengths may be set.
$CC8LC00
Code 128 Length Control = Variable Length
$CC8LC01
Code 128 Length Control = Fixed Length