Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good 
read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms 
increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read 
LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with 
leading ze
roes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming 
Mode
.
4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in 
Appendix D, Keypad
 representing the 
duration which was determined in the steps above. Y
ou will hear a two-beep indication 
after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code 
to abort and not save the entry string. You can then start again at the 
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming 
Mode.
This completes the procedure. See the table below for examples of how to set this feature.
Table 17. Good Read LED Duration Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
Good Read LED 
stays on until 
next trigger pull 
(00)
200ms
1500ms (1.5 
sec
.)
25
00ms (2.5 sec.)
2
Divide by 100 (and pad with 
leading zer
oes)
000 002 015 025
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT GOOD READ LED DURATION SETTING
5
Scan Three Characters From 
Appendix D, Keypad
‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘2’ ‘0’, ‘1’ and ‘5’ ‘0’, ‘2’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE