7.2 Set Temp (Temperature control)
Select MAIN menu then push UP button once
The SP800 automatically controls the main pump and heater to lter the water and maintain it at the
desired temperature set by the user. The user can leave the system to look after the spa and know it
will be at the correct temperature whenever he or she wants to use it.
While viewing the set temp menu item, the current set temperature is displayed on the four numerical
digits in degrees Celsius (default 37.00). The range of adjustment is 10.00 to 41.50 in steps of 0.25
degrees Celsius.
To change the setting press SCROLL while viewing the set temp menu item. The current setting will
ash indicating that the value may now be changed. Use the UP and DOWN buttons to adjust the set
temp as required. Hold down either button for automatic key press repeat. Press the SCROLL button
once the desired value is reached. The nal press of the SCROLL button will return you back to the
default view (out of the menu system) and the new setting will take effect immediately.
Note: The pool temperature will be maintained close to the set temperature, but how close depends
upon the “Heat Control” setting (see section 7.9.2 for more details).