3
Icons
Alarm Bell — Appears when setting an alarm. Blinks on and off
when an alarm is triggered.
Graph — Indicates that graph mode is currently being displayed.
2ND — Indicates that 2ND was pressed and all the alternate key
functions (printed above or below each key) can be used.
Antenna — Displays the current status of the console’s reception.
Antenna with waves indicates signal from a station. Antenna with
no waves indicates resynchronization. No antenna means loss of
signal.
Arrow — Indicates the current variable selected or the variable
currently being graphed if in graph mode.
Umbrella — Appears when it is currently raining.
GRAPH
2
ND

Other manuals for DAVIS Vantage Vue

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DAVIS Vantage Vue and is the answer not in the manual?

DAVIS Vantage Vue Specifications

General IconGeneral
Wind Speed Range2 to 150 mph (3 to 241 km/h)
Rain Collector Resolution0.01 in (0.2 mm)
Rain Collector TypeTipping bucket
Update Interval2.5 seconds
Temperature Accuracy±1°F (±0.5°C)
Humidity Accuracy±3%
Wireless Transmission Rangeup to 1000 ft (300 m)
Humidity Range1 to 100% RH
Wind Direction0 to 360°
Wind Direction Accuracy±3°
Power SupplySolar-powered with battery backup
Console DisplayLCD with backlight
Power (Console)3 C batteries or AC adapter
Wind Speed Accuracy±2 mph (±3 km/h) or ±5%, whichever is greater
Solar Radiation SensorNot included
UV SensorNot included
Rain Measurement Accuracy±4% at rates up to 2 in (50 mm) per hour