S P A Z I O
Operatinginstructionsandwarnings
15
valuesandrestorealldefaultvalues,proceedasfollows:
Instruct. Function
Display
Thecontrolboardisreadytoreceiveinstructions
Scroll down the parameters until you visualize
P007
Confirm! The control board awaits a further
confirmation
ConfirmbypressingontheOKbutton.Theproce-
durestarts
Allparametersarenowsetattheiroriginalvalue
Scrolldowntheparametersuntilyouvisualise“----
”.Thecontrolboardawaitsfurtherinstructions
•• Safety devices
DEAcontrolboardallowsfitterstosetupinstallationsthat
trulycomplywithEuropeanregulationsconcerningautomated
garagedoorsandgates.Morespecifically,thiscontrolboard
allowsyoutocomplywiththelimitssetbythesameregulations
astoimpactforcesincaseofcollisionwithobstacles.
DEA control board is equipped with a built-in anti-crush
safetydevicethat,associatedtothepossibilityoftuningupthe
motors’speed,allowsyoutocomplywiththelimitsimposedby
theabovementionedregulationsinmostinstallations.
Inparticular,youcanadjusttheanti-crushsafetydevicesen-
sitivitybyproperlysettingthevalueassignedtothefollowingpa-
rameters(seealso“Personalizationofworkingparameters“):
•P014motor1forceinopening:from30(min.force,maxsen-
sitivity)to100(maxforce,neutralizedsensitivity)
•P015motor1forceinclosing:from30(min.force,maxsensi-
tivity)to100(maxforce,neutralizedsensitivity)
Incasethegatestructuralfeaturesdonotallowyoutocomply
withtheaboveforcelimits,itispossibletouseexternalsafety
devicesinputs.SICinputscanbeconfiguredbyproperlysetting
parameterno.18:
•P018=0rib”modefunctioning:whentheinputisactivated
themovementdirectionofthemotorsisinverted.
•P018=1“photoelectric barriers” mode functioning: when the
inputisactivated,themotorstops.
If SIC input is unused, it is necessary to short cir-
cuitittocommon.Ifyoupowerexternalsafetydevices
through24VSICoutput(terminalno.22),theirproper
workingistestedbeforeeachmanoeuvre.
•• Messages shown on the display
Control board allows you to visualize on the display several
messagesconcerningitsworkingstatusandanymalfunction:
6 SPARE PARTS LIST
Thelistofsparepartsthatcanbeorderedisadetailedlist
thataccompaniestheexplodedviewoftheproductandmustbe
usedtoorderspareparts.
Thefollowingdatamustalwaysbeprovidedwhenordering
spareparts:
• thecodeoftheproduct(seenontheproductlabel;seeF5,
Page46),
• thepart’spositionnumberintheexplodedview,
• ifavailable,theproduct’spurchasedatemaybeusefulin
somecases.
7 COMPLETE CLOSING ASSEMBLY
Thischapterillustratesthetypicalinstallationofacomple-
teautomatismfor thepurpose ofinforming andassistingthe
installerintheselectionofthevariouspartstobeusedincom-
pliancewithMachineryDirective(2006/42/CE)andEuropean
SafetyStandards(EN12453-EN12445-EN12604)forgate
installation.
Thedataprovidedinthischapterareneithercompletenor
exhaustive,andDEASystemdeclinesallliabilityforanyerrors,
omissionsorinaccuraciesthatmayoccur.
7.1 Minimum level of protection provided by the
safety edge
Theriskofgettingcrushedbetweenthegateandthefence
orwalland/orotherfixedpartsisamongthemostseriousrisks
tobeconsideredwhenautomatingaslidinggateis.Anappro-
priatetypeofoperatingcontrolboardmustbeusedaccording
tothegatetypeanduseagainstsuchrisk,asprovidedforbythe
quotedregulations(see“OPERATINGCONTROL”table).
7.2 Scissoring in side arms
Theriskofscissoringonsidearmsisarelevantriskonau-
tomated overhead doors. The above-mentioned regulations
prescribetheimplementationofoneofthefollowingsolutions
againstsuchrisk:
•ensurethereisnopointofscissoringbetweenthetelescopic
armsandthedoorarmsnorwiththeframenorwiththedoor
(F10page48);
•useadequateprotectionforyourhandsinthearea;
•thisprotectionisnotrequirediftheinstallationisinaprivate
homewhichdoesnotgiveontoapublicareaandthereisno
timer-setautomaticclosing.
7.3 Impact in the opening/closing area
Installapairofphotocellsononeortheothersideofthe
gateoronbothinordertoavoidtheriskofimpactwiththegate
intheclosingarea.(recommendedheight:500mm)inorderto
detectthepresenceofthetestparallelepiped(height:700mm)
positionedasshowninF11onPage48.
Note.Thepresencedetectiontestsampleisaparallelepiped
with3sideswithlight-colouredreflectingsurfacesand3sides
withdark-coloured,opaquesurfaces.
Makesurethereisnoconflictwhenthephotocellsareinstal-
ledonbothsides.Thesystemworkingonthegatesidewherethe
testsampleispositionedmustdetectalltestobjects.

Table of Contents