S P A Z I O
Operatinginstructionsandwarnings
16
“OPERATING CONTROL” table
Type of use
Type of control
Informed users
(private areas)
Informed users
(public areas)
Uninformed users
Person-present control Pushbutton control Pushbutton control with key
The person-present control is
not possible
Pulse control with the gate in
sight
Force limitation
or
presence detectors
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Pulse control with the gate
not in sight
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Automatic control
(i.e. control with
timed closing)
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Messagesshownonthedisplay
Message Description
MESSAGES CONCERNING WORKING STATUS
Closed
Open
Openingunderway
Closingunderway
Whileinstep-by-stepmode,thecontrolboardawaitsfurtherinstructionsafterastartcommand
Stopinputactivated
SICactivatedwhileworkinginbarriermode
ERROR MESSAGES
Message Description Possible solutions
Theypointoutthatthegatehasexceeded:
- (Err1), the max allowed number of reversals (50)
withouteverreachingtothelimitswitch;
- (Err2)the maxnumber ofuninterrupted operations
(10)oftheanti-crushsafetydevice;
Thereforean“emergencymaneuver”isunderway:the
controlboardsetsautomaticallythemotorsinaslow
downphaseandsearchestothelimitswitchinorder
toresetthepositioningsystem.Oncetothelimitswitch
whileclosingarefoundagainthemessagedisappears
andthecontrolboardawaitsfurtherinstructions“----”
andthenresumesworkingnormally.
In case the gate is not properly closed after the emergency maneuver
(maybebecauseoffalsestopsorobstaclesduetomechanicalfrictions),
proceedasfollows:
-Disconnectthepowersupply,checkmanuallythatnoparticularfrictions
and/orobstaclesarepresentduringthecompletestrokeofthedoor/gate.
Leavethedoor/gatehalf-open.
-Connectthepowersupplyagainandsubsequentlygiveastartpulse.At
thispointthedoor/gatewillstarttocloseinslowdownphaseuntilreaching
tothelimitswitch.Makesurethatthemaneuverisproperlycompleted.
Adjustforceandmotorspeedvalues,ifneeded.
Ifthe gate keepsworking inappropriatelytry torepeat themotor stroke
memorizationprocedure
Externalphotocellsand/orsafetydevicesareactivated
oroutoforder
Makesurethatallsafetydevices and/or photocells installed are working
properly.
Themotorisnotconnectedoritsignalscontrolboard
failure
Makesurethatthemotorisproperlyconnected.Ifthemessagereappears
changethecontrolboard.
Voltageofthecontrolboardpowersupplyisbeyond
admittedrange
Ensurepowersupplyvoltageonfastonconnections1-2isequivalentto22V
+/-10%andonfastonconnection3-4isequivalentto27V +/-10%.
Themotorisprobablyoverheatedbecausesomething
hindersthedoortravelrange.
Thecontrolboarddoesnotreacttocommands
Remove any obstacle and wait until message “bLOC” replaces message