2 Tecnical Specifications 4
2 TECNICAL SPECIFICATIONS
2.1 CERAMIC FURNACE UNIT
Supply voltage depending on the type (rating plate on the rear):
~ 230 V 220…240 VAC / 50 – 60 Hz
~ 115 V 110…120 VAC / 50 – 60 Hz
~ 100 V 95…105 VAC / 50 – 60 Hz
Power consumption maximum 1450 W with pump
Fuses according to type
~ 230 V 2 x 6,3 A T 250 V
~ 115 V 2 x 16 A T 500 V
~ 100 V 2 x 16 A T 500 V
Battery Lithium-cell 3,6 V / 2000 mAh
Vacuum pump connection
socket according to type
Interfaces serial (with the PC) or printer
Soft or memory module (same construction)
Max. firing temperature 1,200°C
Max. rate of temperature rise 160°C/min from 20°C to 500°C
120°C/min from 500°C to 1000°C
60°C/min from 1,000°C to 1,200°C
Dimensions 35 x 63 x 28 cm (W x H x D, D4)
35 x 74 x 28 cm (W x H x D, D4press)
Weight 18.0 kg (D4)
18.5 kg (D4press)
2.2 VACUUM PUMP UNIT
Pump type Service-free diaphragm pump
Supply voltage depending on the type
(pump rating plate on the rear):
~ 230 V 220…240 VAC / 50 – 60 Hz
~ 115 V 110…120 VAC / 50 – 60 Hz
~ 100 V 95…105 VAC / 50 – 60 Hz
Ultimate pressure < 30 hPa
Weight 6 kg
DEKEMA assumes no liability for damage arising from the use of a different vacuum
pump than the one supplied.