Error Code Message Information
PSU0037
Message Fan failure detected on power supply <number>.
LCD Message Fan failure detected on PSU <number>. Check PSU.
Action Check for fan blockage. If the problem persists, see Getting Help.
PSU0076
Message A power supply wattage mismatch is detected; power supply <number> is rated for
<value> watts.
LCD Message PSU wattage mismatch; PSU <number> = <value >watts
Details Power supplies should be of the same input type and power rating.
Action Install matched power supplies and review this manual for proper conguration.
PSU1201
Message Power supply redundancy is lost.
Details The power supply tries to operate in a degraded state. System Performance and power
redundancy may be degraded or lost.
Action Check input power. Reinstall the power supply. If the issue persists, see Getting Help.
PSU1204
Message The power supplies are not redundant. Insucient resources to maintain normal
operations.
LCD Message PSU redundancy degraded. Check PSU cables.
Details The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
Action Check the event log for power supply failures. Review system conguration and power
consumption.
PWR1004
Message The system performance degraded because power capacity has changed.
Details The system may power down or operate in a performance degraded state.
Action Check the event log for power supply failures. Review system conguration and power
consumption and upgrade or install power supplies accordingly.
PWR1005
Message The system performance degraded because the user-dened power capacity has
changed.
Details The user-dened power settings have aected system operation.
Action If unintended, review system conguration changes and power policy.
PWR1006
Message The system halted because system power exceeds capacity.
LCD Message System power demand exceeds capacity. System halted.
Details The system halted because system power exceeds capacity.
Action Review system conguration, upgrade power supplies or reduce system power
consumption.