WARNING: Make sure the battery is installed in a secure location and 
follows all local fire codes and regulation. Read the safety instructions 
that is shipped with the battery.
WARNING: Only a trained technician should setup/replace the battery.
WARNING: Only install the battery inside an enclosure that meets fire 
safety requirements.
WARNING: Only Sealed Lead Acid (SLA) battery rated 50Ah (or less) 
should be used
WARNING: During installation, before connecting a 24V Power or 
19.5V power source, install a 15A or 20A circuit breaker or fuse on the 
mains power distribution circuit-panel circuit.
Wiring Design Procedure
NOTE: It is recommended that the cable connecting the power module 
to the battery be able to carry 15 A of current as per the AWG standards.
NOTE: It is recommended to include a 15 A breaker/fuse between the 
Power Module and the battery.